3 1/2digit LED display with auto temperature compensation,combination pH electrode & RTD
probe,( Table model )
Didital pH Meter DR-313
3 1/2digit LED display with
manual temperature compensation, combination pH electrode,( Table model )
Digital ph conductivity & Temperature meter DR 315
For measurement of pH, Conductivity and Temperature. 3 digit LED display with pH combination electrode. Cond
cell and temoerature probe (Table Model)
UV-VIS SPECTROPHOTOMETER DR 324 C
The perfectly designed double beam DR 324 C UV/VIS SPECTROPHOTOMETER successfully realizes
high accuracy and reliability measurement to meet various application requirements. It can be used extensively for
qualitative and quantitative analysis in such fields as biochemical research and industry, pharmaceutical
analysis and production, education, environmental protection, food industry, clinical examination, sanitation
and antiepidemic etc.
Salient Features
Wide wavelength range, satisfying requirements of various fields
Fully automated design, realizing the simplest measurement & satisfying the requirements of pharmacopoeia.
Maximum of 9 wavelenths & 7 samples scan be measured at one time.
Automatic change-over between W lamp & D 2 lamp
Optimized optics and
large scale integrated circuits design, light source and receiver from world famous measurement all add up to
high performance and reliability
Rich measurement
methods:wavelength scan, time scan, multi-wavelenth determination, multi-order derivative determination,
double-wavelength method and triple-wavelength method etc., meet different measurement
requirement.
Automatic 10mm 8-cell holder
Data output can be
obtained via a printer port and a RS-232 interface
Parameters and data can be saved for
user's convenience
PC controlled measurement can be achieved for more accurate and flexible
requirement
Technical Specifications
Wavelength Range
190-1100 nm
Spectral Bandwidth
1 nm
Working Mode
T,A,C,E
Optical System
Double beam
Scanning Speed
Fast / Medium
/ Slow
Photometric Range
-0.3 - 3.5 A, 0 to 220 %T
Wavelength Accuracy
+0.3 nm
Wavelength Reproducibility
< 0.10 nm
Photometric Accuracy
+ 0.3% T (0-100% T) +0.002 A (0-0.1 A)
Photometric Reproducibility
< 0.15 % T
Stray Light
< 0.1% T (Nal. 220nm, NaNO2 340 nm)
Baseline Flatness
+ 0.002 A
Stability
< 0.001A/h (at 500 nm, after warming up)
Noise
+0.001A (at 500 nm, after warming up)
Detector
Dual Silicon Photodiode
Display
6 inches high light blue LCD
Power
AC:220V + 10%, 50 Hz.
Dimensions
630 x 470
x 210 mm
Weight
26 Kg
Accessories
Glass Cells
16 No.
Quartz Cells
4 Nos.
Fuse
3 Nos.
Instrument Cover
1 No.
Software CD
1 No.
RS 232 Cable
1 No.
Operation Manual
1 No.
TDS Meter DR347
Digital TDS Meter DR-347
3 1/2digit LCD display, cell constant
adjustment along with TDS Cell mains operated
Portable Digital TDS Meter DR-347 A 3 digit LCD display, along with TDS Cell Battery
Operated.
Digital Conductivity Meter DR-342
Deluxe Conductivity Meter DR-342
With auto temperature compensation 3 1/2 digit LED display, digital cell constant adjustment conductivity cell and
temperature probe
Digital Conductivity Meter DR-343
3 1/2 digit LED display in 5 ranges along
with Coductivity Cell digital cell constant display adjustment, facility for temperature compensation.
Digital Conductivity Meter (portable)
DR-345
3 1/2digit LCD display along with conductivity cellbattery operated
Flame Photometer
Digital Flame Photometer DR-332
With filters Na & K.
2 digit LED display along with compressor and other acessories
By Oil free mini compressor unit with pressure
regular
Combustion
LPG controlled by precision regulator
Power
230V +10% AC 50 Hz
Size
(LxBxH)
275 x 192 x 240
mm
Weight
9 Kg (Approx.)
Accessories
Instrument with Na & K Filters, Instruction Manual, Dustcover, Chimney,
Air Tubing
Product Range
Photo Colorimeters, Spectrophotometers, Digital pH Meters,
Conductivity/TDS Meters, Turbidity Meters, Digital D.O. Meters, Water & Soil Analysis Kits
Digital Clinical Flame Photo
Meter Dule Channel DR-333
With Na & K filiters. Results in meq/I
for medical use. 2 digit LED display with compressor and other accessories.
Microprocessor Flam Photometer DR-334
With
Soldium (Na) and Potassium (K) filters, 3 point calibration, direct readout in ppm & meq/l, auto filter selection, auto
ignition, 5 digit LED display. It is supplied with compressor and other accessories for lab & medical use. Ca & Li filters
can be provided at extra cost
Digital Colony Counter DR 185
Digital Colony Counter is
designed for quick and accurate counting of bacterial and mould colonies in Petri dishes. Feature packed & easy to use,
this is an indispensable bench top tool for the busy microbiologist. It is designed for rapid and accurate counting of
bacterial and mould colonies. Simply place the Petri dish on the illuminated pad and touch the dish with the pen provided
to mark each colony in turn.
This causes a count to be registered on the digital
display and audible tone confirms each count made. Marking the dish with the pen avoids missing colonies or double counting.
The digital count on the display can be reset manually any time by pressing the RESET key provided. Optimum viewing of
colonies is aided by peripheral glare-free illumination. An integral magnifying glass provides for easier counting of
small
Salient Features
· 110mm Dia Magnifying Glass
· Audible Confirmation of each Count
· Uniform Readout from 0.9999
· Auto Marker Pen
· Wolffhuegel Glass Grid with Focusing Facility
Specifications
Digital Display
4
digit, 999 Max. Count
Dish Size
110 mm
Magnification
x 1.7
Dimensions
L 274 x B 320 x H 167 mm
(approx.)
Weight
3 kgs. (approx.)
Packaging
23 cm x
28 cm x 20 cm
Power
230V - 10% AC, 50 Hz, 40W
Accessories
Marking Pen (1
No.),
Magnifier Lens (1 No.)
Auto Kari Fischer Titrimeter DR 336
Microprocessor K. F. Moisture
Titrator DR-335
with built in magnetic stirrer. Auto
computation of moisture in ppm, %age and mg H20, Storage of Date, time, Batch No. & final results of 20 titrations. K. F.
reagent dispensing by motorised process. Final results are flashed on 8 digit digital display. External printer attachment
facility available.
Auto Kari Fischer Titrimeter ( Deluxe Model ) DR-336
Having control and
stirring units with array of 10 LED's buzzer, auto zero burette, adjustable timer, dual platinum electrode and other
accessories.
Auto Kari Fischer Titrimeter DR-336 A
With control and
stirring, auto zero burette, adjustable timer, dual platinum electrode and other accessories.
Spectrophoto Meter Single Beam DR-324
Digital
Spectrophotometer DR 324
Range 340 to 960 nm with facility for Automatic concentration, %
Transmission & O.D. measurement. Wavelength resolution 5 nm. 3 digit LED display with round test tubes.
Digital
Spectrophotometer DR-324 B
Range 340 to 960 mm with facility for Automatic Concentration %
Transmission & O. D. measurement. Separate 3 digit LED display for wvelength with 1nm. Resolution 3 digit LED display with
round test tubes.
MICROPROCESSOR UV-VIS SPECTROPHOTOMETER DR- 324G
UV-visible spectrophotometer, an analytical instrument commonly used in physico-chemical laboratories to make quatitative
and qualitative analysis of specimen material in the ultraviolet, visible specteral range finds much scope fer its service
in such fields as medicines, clinical examination, biochemistry, petro chemical industry, Bio-technology, Enviromental
protection & quality control. the technique has enjoyed a molecular biology and the need to quantify DNA & protiens. Here,
the simplicity of use, the non distructive nature of the sampling and the cost effectiveness of the measurement has proved
very beneficial in the modern laboratory.
Technical Specifications
Wavelength
195 to 1000nm
Spectral Bandwidth
2 nm
Accuracy
+ 0.5 nm
Repeatability
+ 0.3 nm
Resolution
0.1 nm
Photometric Range
% T:0 to 100%, Abs.:0 to 1.999
Conc.: 0 to 1999, K-Factor:0 to 1999
Accuracy
+0.005 Abs at 1.0 Abs +0.010 Abs
at 1.0 Abs
Stray Light
Less thn 0.1% Abs at
320 nm
Readability
+ 1 Count
Data Readout
Single Line LCD
display
Key Board
4 Keys, Soft touch
membrane type
Painter Interface
Printer
interface for any printer
Serial
Interface
RS 232C interface
Light
Source
a) Tungsten Halogen Lamp
b) Deuterium Lamp (D2)
Detector
Wide range Silicon Photodiode
Optics
Complete mirror optics with resolution 1200
groove/mm grating
Sample Holder
4 position
adjustable sample holder
Power
230V +
10%, 50 Hz. AC
Dimensions
420 x 350 x 240 mm
(lxbxh) Approx.
Weight
10 Kg
(Approx.)
Product Range
Photo Colorimeters, Spectrophotometers, Digital pH Meters,
Conductivity/TDS Meters, Turbidity Meters, Digital D.O. Meters, Water & Soil Analysis
Kits
WATER & SOIL ANSLTSIS KIT DR 321
DR 321 Water and soil
analysis kit measured pH,ORP,Conductivity, TDS, Salinity, Dissolved Oxygen and Temperature ( Without ORP Electrode ) Seven
Parameter
DR 321 A Water and soil analysis kit measured pH,ORP,Conductivity, TDS, Dissolved Oxygen and
Temperature ( Without ORP Electrode ) Six Parameter
DR 321 B Water and soil analtsis kit measured pH, ORP,
Conductivity, TDS and Temperatur Five Parameter
DR 321 C Water and soil analysis kit measured pH,ORP,Conductivity, and Temperature
Four Parameter
Melting Point App. ( Digital)
Digital Automatic Melting Point Apparatus is
designed for quick and accurate detection of melting point. Feature packed & easy to use, this is an indispensable bench
top tool. This equipment has an arrangement to hold the capillary containing the sample in uniformly heating media. the
temperature is indicated on a digital display readable in 1.0oC. At the point, whn the sample melts, the heating is
automatically cut-off and the digital display showing the temperature remains on the indicator till it is cleared. No
Silicon oil or other bath is required as heating media. Range 2.0oC above room temperature to 350oC.
Salient Features
· Fully Automatic
· Latest Technology
· Range upto 350oC
· Highly
Accurate
· No Silicon Oil/ Heating Media Required
Specifications
Display
Digital 3 1/2 Digit, Bright LED
Accuracy
1%
Operation
Fully Automatic
Dimensions
L 405 x B 360 x H 235 mm (approx)
Weight
5 Kg (approx.)
Power
230V + 10%AC, 50Hz
Accessories
Capillary Tube - 100 No.
Cleaning Tool - 1 No.
Microprocessor Flamephotometer DR 335
FEATURES Extremely useful for medical and agriculture laboratory use
All element measurement in single aspiration of the sample
Automatic Optical Management of
filters
Calibration curve programmability using maximum of 5 standards.
Data processing through curve fitting techniques – least squares, quadratic
Multiple calibration curves saving facility
Samples data storage facility
Printer Attachment Facility
Measures in
ppm, mg, % and meq
Help key available at each and every operating step
SPECIFICATIONS
Range
(ppm)
(meq)
Na: 0-100
Up to 250 meq/l, 1:100 dil
K: 0-100
Up to 250 meq/l, 1:100 dil
Ca:
0-100
Up to 250 meq/l, 1:100 dil
Sensitivity
Na:0.1ppm, K:0.01 ppm,
Ca:0.5 ppm
Units
ppm, mg and % age Selectable
Filter Selection
Na & K and Ca by Microprocessor controlled stepper
motor
Reproducibility
±1% of FS ± 1 Digits
Curve fit accuracy
± 2% of FS
Display
Large 20 x 4 Character LCD display with backklit
Aspiration time
4-5 Seconds
Flame system
LPG & Dry oil
free air
Detector
Photodiode
Calibration
Up to 5 point calibration with curve fitting software
Gas Control
Adjustable with knob
Ignition system
Auto ignition
Fuel Gas
LPG
Burner
Stainiless Steel
Dimensions
365 X 245 X 220mm Approx. (LxBxH)
Printer
Provision for attachment of Dot-Matrix Printer or HP LaserJet
/ inkjet printer (non-win printers) with centronics parallel interface.
RS 232 interface
Available (PC software at extra cost)
Air Compressor
with Built-in Regulator and Air Filter to deliver stable and moisture/oil
free air supply @ 1Kg/cm2
Air Supply
By oil free Mini Compressor
Unit With Pressure Regulator
Weight
Main Unit : 8 Kg.
(Approx) compressor : 6.5 kg. (Approx)
Power Supply
95 to
270V A 50-60Hz with inbuilt stabilizer
pH Meter With Touching LED DR 316
Characteristic:
1.With touching LCD displaying, operation easy;
2.To select one or more PH buffer solutions to calibrate the meter;
3.With more calibration functions (max/mum five points calibration);
4.RS-232 interface;
5.Protection from electricity cutting
off;
6.Measuring results can be stored, deleted,
viewed、communicated and printed.
Specification:
1. Measuring range:
pH: (-2.000~18.000)pH
mV:
(-1999.9~1999.9)mV
T: (-5.0~105.0) ℃
2. Accuracy :
pH:0.002pH±1 bit
mV: ±0.03%(FS)
±1 bit
T: ±0.2℃±1 bit
3. Resolution:
pH: ±0.001pH
mV:±0.1mV
T: ±0.1℃
4.
Range of temp. compensation: (-5.0~105.0) ℃
5.Measured
solution temperature: (5~60) ℃
Microprocessor Flam Photometer DR-334
Microprocessor Flam Photometer DR-334 With Soldium (Na) and Potassium
(K) filters, 3 point calibration, direct readout in ppm & meq/l, auto filter selection, auto
ignition, 5 digit LED display. It is supplied with compressor and other accessories for lab & medical use. Ca &
Li filters can be provided at extra cost
SPECIFICATIONS:
Range
PPM
Meq/I
Serum Urine
Na: 0.1 - 100
Na: 0.1 -
100
0.87-870
K: 0.1 – 100
0.256-256
0.512-512
Ca: 15 – 100
Li: 0.5 - 100
0.724-144.8
---------------------------
SENSITIVITY
0.1
ppm
ACCURACY
±1% up to 40
ppm
±2% above 40 ppm
READOUT
5 digit seven
segment bright red LED display
FLAME SYSTEM:
LPG & Dry oil free
air
DETECTOR:
Photodiode
CALIBRATION:
3 point calibration
COMBUSTION GAS
LPG
DIMENSION:
370 X 250 X 225 mm Approx. (LxBxH)(UNIT)
DIMENSION:
370 X 360 X 300
mm Approx. (Compressor)
AIR SUPPLY:
oil free Mini Compressor With Pressure
Regulator
BURNER:
Made in Stainless Steel
POWER:
230V ±10% AC,50Hz
WEIGHT:
18 Kg. (Approx)
Standard
Accessories
Sample Holder (5 No.), Dust
Cover, Mains Lead, Chimney, Capillary Tubes (3 No. S), Air and Gas Tubing along with End clamps (1 set),
cleaning Wire, Instruction Manual
UV-VIS Spectrophotometer- Double Beam DR 324 D
UV-VIS Spectrophotometer- Double Beam DR 324 D
Is advanced DOUBEL BEAM UV-VIS Spectrophotometer with more accuracy and flexible requirements. The two
detectors are used to measure sample and reference respectively and simultaneously for optimizing
measurement accuracy. It has vide wavelength range satisfying requirement of various fieds, Such as
biochemical research and industry, pharmaceuticals analysis and production, education, environment protection, food
industry etc.
Technical Specifications
Optical System
Double Beam (1200 Lines/mm Grating)
Wavelength Range
190-1100nm
Mode
Basic/Quantitative/Wavelength Scan/ DNA Protein Test/Kinetics
Scanning Speed
Fast/Medium/Low
Band
Width
1 nm
Wavelength Accurach
± 0.1 nm
Wavelength Repeatability
0.1 nm
Photometric Accuracy
± 0.3%T
Photometric
Display Accuracy
0.2%T
Photometric Display Range
0-200% T, -0.3-3.0 A, 0-9999
C
Stability
0-001 A/h @ 500 nm
Baseline Flatness
±0.001 A
Noise
±0.001 A
Stray Light
-< 0.05 % T @ 220 nm,
360 nm
Data Output Port
USB
Printer Port
Parallel Port
Display
Graphic LCD (320 x 240 Dots)
Lamps
Deuterium Lamp & Tungsten Halogen Lamp
Detector
Silicon Photodiodes
Dimension (L x W x H)
625 x 430 x 206
mm
Net Weight
26kg
Accessories
Glass Cells: 4
No.
Quartz Cells: 4 Nos.
Fuse: 2 Nos.
Instrument Cover: 1 No.
Software CD: 1 No.
USB Cable: 1
No.
Operational Manual: 1 No.
Basic Mode
To measure the Absorbance and
Transmittance
Quantitative
Coefficient Method
Standard Curve
Up to 10 standard samples
may be used to establish a curve.
Four methods for fitting a cuver through the calibration
paints
Linear fit, Linear fit through zero, Square fit and cubic fit.
DNA / Protein Test
Concentration and DNA
purity are quickly and easily calculated: Absorbance ratios 260 nm / 280 nm with optional subtracted absorbance
at 320 nm. DNA concentration=62.9 x A260-36.0 x A280 Protein concentration=1552 x A260 - 757.3 x
A280
Wavelength
Scan
The wavelength scan intervals are 0.1, 0.2, 0.5,
1, 2, 5 nm
Hi, Medium and Low scan speeds are availabe. They vary from100 to 3600 nm /
min.
Wavelengths are scanned from high to low so that the instrument waits
at high WL. and it minimizes the degradation of UV sensitive samples.
Kinetics
This mode may be used for time course
scanning or reaction rate calculations. Abs vs time graphs is displayed on the scren in real time.
Wait time and measurement time up to 12 hours may be entered with time intervals of
0.5, 1, 2, 5, 10, 30 seconds and 1 min. Post-run manipulation includes re-scaling, curve tracking and selection
of the part of the curve required for the rate calculation. Rate is calculated using a linear
regression algorithm before multiplying by the entered factor.
Microprocessor Based pH Meter
Microprocessor Based pH Meter DR 312 (3 Digit Display & 4
Digital Display Rang0-14 pH & 0-1999mV Resolution 0.01pH/1mv/0.1Deg C) Temp. Compensation 0-100 Deg C,
Auto/Manual, Calibration Automatic with Battery Backup for Memory with Standard pH Solution for
Calibration
TECHNICAL SPECIFICATIONS
Function
pH OR mV & temperature simultaneously
Display
16 character x 2 lines Alphanumeric
BL LCD
Range
pH 0-14.00
mV:-1999 mV to +1999 mV
Temp.: -50.0oC
to 200oC
Resolution
0.01 pH
1 mV
Temp.:±0.1ËšC
Accuracy
±0.01 pH
± 0.1% ± 1 digit mV
Temp. ±0.1% of range ±1 digit
pH Calibration
auto as manual, 3 point / 2 point
(Programmable)
Temp. & mV Calibration
two point manual
Auto buffer recognition
4.00 pH, 7.00 pH, 9.20 pH
Slope adjustment
80% to 20% Nu default 100%
Temp. Compensation
0 to 100oC Auto with temp probe / Manual with ekys
DOUBLE R. OPTICS & SCIENTIFIC WORKS
73, PREET NAGAR, NEAR RAJA PARK, AMBALA CANTT. Tel. No. 0171-20009594, 2602631 Fax. No. 0171-2602631, 2640938, Mobile No. - +91-94160-20432